Saniflo Sanicubic 1 Grinder
Saniflo Sanicubic 1 Grinder is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Product Description
The Sanicubic 1 is a 1 HP heavy duty grinder system used to pump waste water from several bathrooms and fixtures, with the ability to pump 36ft vertically and up to 328ft horizontally it can handle the most challenging situations. With its heavy duty grinder it is an excellent choice for commercial or residential applications where sanitary napkins or condoms may be disposed. A very popular system for adding facilities to pool houses or detatched garages.
Maximum pumping distances are 36 Ft vertically and/or 328 Ft horizontally.
The inside of the Sanicubic 1 comprises of a couple of pressure switches and a circuit board assembly, which starts and stops the unit, a powerful motor, which drive the stainless steel cutting blade and the pump. The motor is sealed for life in an oil filled enclosure. A common spindle/shaft drives the impeller and the macerator blade. The moving parts therefore are kept to an absolute minimum. Water and organic waste matter that enter the enclosure are reduced to slurry and are picked up by the impeller mounted beneath the motor.
The pump is able to handle up to 50 gpm. If the incoming rate is higher than the discharge rate, the pump automatically signals the “alarm” stage. This will activate the visual alarm mounted on the pump’s control panel and the audible alarm from the wired control box (if connected).
The Sanicubic 1 can be retrofitted into an existing sewage ejector basin of at least 24” in diameter for a quick and easy pump exchange. As this is considered a “plug and play” device, no chains or floats are needed.
Note that the effluent pipe leading into the pump has to be installed with the required ¼” per foot gravity flow. There must be a 10” height difference (from pump to connecting fixture) if the drain is connected to the bottom inlet.
The wastewater from other sanitary fixtures is discharged into the Sanicubic 1 via four 1½-inch or 4” inlets, on either side of the housing and on the top of the enclosure. The internal discharge pipe comes equipped with a check valve that prevents back flow into the unit. Isolating valves (ball, gate valves) must be installed on waste inlets and on the discharge pipe to ensure that any service/maintenance may be carried out safely.
This unit has been designed with a 1-1/2” vent connection on the top of the enclosure. All plumbing codes require connection to a vent system. Please note that the vent system should be a two-way air vent. The use of mechanical vents, air admittance valves or similar devices are not permitted as these are considered one-way air vent systems.
The Sanicubic 1 has been certified to American and Canadian Standards. Macerating standard; US: CSA Certified & IAPMO (UPC) listed - ASME A112.3.4, CA: Macerating Standard CSA B45.9., Waterproof Enclosure IP68 Rated
Download the Installation manual: Sanicubic 1 Manual
Download the Complete Spec Sheet: Sanicubic Specs
The Sanicubic 1 is ordered as a single unit only. No other fixtures are included. The Saniflo Rear Discharge Bowls will work with the Sanicubic unit and are available as a kit if necessary, just call to get a quote on the complete setup. 866-658-0505
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.